[Date Prev][Date Next]
[Chronological]
[Thread]
[Top]
Re: delta-syncrepl replica out of date
Francis Swasey wrote:
On 10/24/07 4:36 PM, Quanah Gibson-Mount wrote:
--On October 24, 2007 3:22:21 PM -0400 Francis Swasey
<Frank.Swasey@uvm.edu> wrote:
Please post your configs.
They have changed very little since the first posting. Here they are
though (as attachments)
Your "retry" setting looks strange. Can you fire up slapd with -d 64
(config file processing) and check:
"If an error occurs during replication, the consumer will attempt to
reconnect according to the retry parameter which is a list of the <retry
interval> and <# of retries> pairs. For example, retry="60 10 300 3"
lets the consumer retry every 60 seconds for the first 10 times
and then retry every 300 seconds for the next 3 times before stop
retrying. The ‘+’ in <# of retries> means indefinite number of retries
until success."
Yours is:
retry=30,+
--
Kind Regards,
Gavin Henry.
OpenLDAP Engineering Team.
E ghenry@OpenLDAP.org
Community developed LDAP software.
http://www.openldap.org/project/